---
title: Salinity to Specific Gravity Converter (ppt ↔ SG) with Chart | Free
url: https://zhukovskyi.space/calculators/aquarium/salinity-to-specific-gravity.html
description: Convert aquarium salinity in ppt to specific gravity and back on the 25/25 °C, 20/20 °C and 60/60 °F scales, with a chart, from the UNESCO EOS-80 equation of state.
---

[Tools](../) › Aquarium

Free aquarium tool

# Salinity to specific gravity

Salinity in ppt to specific gravity and back, on the reference scale of your refractometer or hydrometer, with the density and the salt per litre.

**Quick answer:** 35 ppt (natural seawater) is SG 1.0264 on the 25/25 °C (77 °F) scale of hobby refractometers, 1.0269 on the 60/60 °F hydrometer scale. A reading of 1.025 at 77 °F is 33.2 ppt and 1.026 is 34.5 ppt. Values from the UNESCO seawater equation of state, EOS-80.

Result

–

SG 25/25 °C (77 °F)–

SG 20/20 °C (68 °F)–

SG 60/60 °F–

Density at 25 °C–

Dissolved salts–

Natural seawater composition. Salt mixes also hold water and differ by brand: follow the package and confirm with a calibrated refractometer.

## Salinity charts and worked example

### Salinity to specific gravity on each scale

| Salinity, ppt | SG 25/25 °C (77 °F) | SG 20/20 °C (68 °F) | SG 60/60 °F | Density at 25 °C | Dissolved salts |
|---|---|---|---|---|---|
| 25 | 1.0188 | 1.0190 | 1.0192 | 1015.8 kg/m³ | 25.4 g/L |
| 26 | 1.0196 | 1.0197 | 1.0199 | 1016.6 kg/m³ | 26.4 g/L |
| 27 | 1.0203 | 1.0205 | 1.0207 | 1017.3 kg/m³ | 27.5 g/L |
| 28 | 1.0211 | 1.0213 | 1.0215 | 1018.1 kg/m³ | 28.5 g/L |
| 29 | 1.0218 | 1.0220 | 1.0222 | 1018.8 kg/m³ | 29.5 g/L |
| 30 | 1.0226 | 1.0228 | 1.0230 | 1019.6 kg/m³ | 30.6 g/L |
| 31 | 1.0233 | 1.0236 | 1.0238 | 1020.3 kg/m³ | 31.6 g/L |
| 32 | 1.0241 | 1.0243 | 1.0245 | 1021.1 kg/m³ | 32.7 g/L |
| 33 | 1.0249 | 1.0251 | 1.0253 | 1021.8 kg/m³ | 33.7 g/L |
| 34 | 1.0256 | 1.0258 | 1.0261 | 1022.6 kg/m³ | 34.8 g/L |
| 35 | 1.0264 | 1.0266 | 1.0269 | 1023.3 kg/m³ | 35.8 g/L |
| 36 | 1.0271 | 1.0274 | 1.0276 | 1024.1 kg/m³ | 36.9 g/L |
| 37 | 1.0279 | 1.0281 | 1.0284 | 1024.9 kg/m³ | 37.9 g/L |

Source: computed with the one-atmosphere international equation of state of seawater, EOS-80 ([Millero and Poisson (1981), Deep-Sea Research 28A: 625–629](https://doi.org/10.1016/0198-0149(81)90122-9); [Fofonoff and Millard (1983), Unesco Technical Papers in Marine Science 44](https://repository.oceanbestpractices.org/handle/11329/109)). SG t/t = density of the water at t ÷ density of pure water at t. Checked 26 November 2026.

### Specific gravity to salinity

| Refractometer or hydrometer reads | Salinity if it is a 25/25 °C (77 °F) scale | If 20/20 °C | If 60/60 °F |
|---|---|---|---|
| 1.018 | 23.9 ppt | 23.7 ppt | 23.5 ppt |
| 1.019 | 25.2 ppt | 25.0 ppt | 24.8 ppt |
| 1.020 | 26.6 ppt | 26.3 ppt | 26.1 ppt |
| 1.021 | 27.9 ppt | 27.7 ppt | 27.4 ppt |
| 1.022 | 29.2 ppt | 29.0 ppt | 28.7 ppt |
| 1.023 | 30.5 ppt | 30.3 ppt | 30.0 ppt |
| 1.024 | 31.9 ppt | 31.6 ppt | 31.3 ppt |
| 1.025 | 33.2 ppt | 32.9 ppt | 32.6 ppt |
| 1.026 | 34.5 ppt | 34.2 ppt | 33.9 ppt |
| 1.027 | 35.8 ppt | 35.5 ppt | 35.2 ppt |
| 1.028 | 37.1 ppt | 36.8 ppt | 36.5 ppt |

The same reading means more salt on a 25 °C scale than on a 60 °F one. Most hobby refractometers are 25/25 °C; check the manual.

### Worked example: natural seawater, 35 ppt

1. Density at 25 °C from EOS-80: 1023.34 kg/m³; pure water at 25 °C: 997.05 kg/m³.
2. Specific gravity 25/25 °C: 1023.34 ÷ 997.05 = 1.0264.

3. On a 60/60 °F hydrometer scale the same water is 1.0269; on 20/20 °C it is 1.0266.
4. Dissolved salts: 35 g/kg × 1.0233 kg/L = 35.82 g per litre, 136 g per US gallon.

**Result: 35 ppt reads 1.0264 on a 77 °F refractometer. A reading of 1.025 is 33.2 ppt.**

Made and checked by [Andrii Zhukovskyi](https://zhukovskyi.space/about/). The source of each table is named under it; assumptions and limits are in the [methodology](../methodology.html). The formulas are the same as in the matching Dre Dev app and are tested against its control values. Web sources were read on 26 November 2026.

## Open data

The full table, every 0.5 ppt from 0 to 45 on all three scales (91 rows), is an open dataset under the [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/) licence: use it anywhere, with credit. Download it as CSV or JSON from [Zenodo (doi:10.5281/zenodo.24547081)](https://doi.org/10.5281/zenodo.24547081).

## More aquarium tools

[Ammonia toxicity chart](../aquarium/ammonia-toxicity-chart.html)

The whole hobby, on your phone

### TankLog: Aquarium Log & Dosing

Log your aquarium's water tests by tapping the numbers on your kit's color chart, see what is off, and how big a water change brings it back. The free-ammonia and salinity tools use these same formulas.

[See the app](https://zhukovskyi.space/apps/tanklog/)

## Questions

What specific gravity is 35 ppt?

1.0264 on a 25/25 °C (77 °F) scale, the one most hobby refractometers use; 1.0266 on 20/20 °C and 1.0269 on 60/60 °F.

What salinity is SG 1.025?

33.2 ppt if your instrument reads on the 25/25 °C scale, 32.6 ppt on a 60/60 °F scale. Find the scale in the refractometer's manual.

Why are there different specific gravity scales?

Specific gravity compares the water with pure water at the same temperature, and both expand as they warm, by different amounts. So the number depends on the reference temperature: 60 °F for many older hydrometers, 77 °F (25 °C) for most refractometers sold for reef tanks.

Is ppt the same as PSU?

Practically, yes. Oceanographers measure practical salinity (PSU, no unit) by conductivity; for natural seawater it equals grams of salts per kilogram of water, parts per thousand, to within about half a percent.

How much salt do I need per gallon?

Natural seawater at 35 ppt holds about 35.8 g of dissolved salts per litre, 136 g per US gallon. Commercial salt mixes need more, because they hold water, and differ by brand: start with the package's dose and check with a refractometer.

Can I use this to correct a hydrometer read at tank temperature?

No. A hydrometer's own glass or plastic expands with temperature too, so the correction depends on the instrument. Use the maker's correction chart, or a refractometer with automatic temperature compensation.

Reference only. A result depends on what you enter and on the published tables named on this page. Before you buy materials, size a circuit, charge a system or dose chemicals, check it against the code in force where you work, the product label and the manufacturer's instructions. These tools come with no warranty.

[Methodology and sources](../methodology.html) · [Checked examples](../verification.html) · [Changelog](../changelog.html) · [Found an error? Tell me](mailto:mobile.support@zhukovskyi.space?subject=Calculator%20error%3A%20Salinity%20to%20specific%20gravity&body=Page%3A%20https%3A//zhukovskyi.space/calculators/aquarium/salinity-to-specific-gravity.html%0A%0AWhat%20I%20entered%3A%0A%0AWhat%20the%20page%20showed%3A%0A%0AWhat%20I%20expected%2C%20and%20where%20that%20number%20comes%20from%3A%0A)
