Dre Dev Tools
Tools › Methodology › Checked examples
Source row → calculator answer

Checked examples

31 rows from the published sources, each next to what the calculator answers for the same input. The answers on this page are produced by the calculators' own code when the site is built.

If an answer falls outside the allowed difference, the build stops and nothing is published. Where the calculator and the source differ on purpose, the row says why. The sources were last read against these rows on 12 November 2026.

You can repeat any row yourself: open the calculator, enter the example and compare. The same list runs as an automated test in the public repository (verification.json).

Superheat & subcooling calculator

ExampleThe source saysThe calculator answersAllowed difference
R-410A: temperature at 118.8 psigR-410A, 40 °F row: 118.8 psig [1]Saturation 40.0 °F (4.4 °C)within 0.05 °F
R-22: pressure at 100 °FR-22, 100 °F row: 195.9 psig [1]Saturation 195.9 psigwithin 0.05 psig
R-32: superheat at 121.0 psig suction, 52 °F lineR-32, 40 °F row: 121.0 psig, so superheat = 52 − 40 = 12.0 °F [1]12.0 °Fwithin 0.05 °F
R-454B: subcooling at 300.8 psig liquid, 90 °F lineR-454B, 100 °F row, liquid (bubble) column: 300.8 psig, so subcooling = 100 − 90 = 10.0 °F [1]10.0 °Fwithin 0.05 °F
R-454B between chart rows: bubble pressure at 42 °F
The chart has a row every 5 °F; the calculator interpolates between rows and shows one decimal.
42 °F: 116.35 psig liquid (bubble) [2]Bubble (liquid) 116.4 psig Dew (vapour) 111.2 psigwithin 0.15 psig
R-454B between chart rows: dew pressure at 42 °F42 °F: 111.22 psig vapor (dew) [2]Bubble (liquid) 116.4 psig Dew (vapour) 111.2 psigwithin 0.15 psig
R-410A between chart rows: pressure at 43 °F43 °F: 125.777 psig [3]Saturation 125.8 psigwithin 0.3 psig

AWG to mm² converter

ExampleThe source saysThe calculator answersAllowed difference
12 AWG in circular mils12 AWG: 6,530 circular mils [4]6,530 cmilexact match
12 AWG in mm²12 AWG: 3.31 mm² [4]3.31 mm²within 0.005 mm²
4/0 AWG in mm²4/0 AWG: 211,600 circular mils, 107.2 mm² [4]107.22 mm²within 0.05 mm²

Wire size calculator

ExampleThe source saysThe calculator answersAllowed difference
50 A load, copper THHN, 75 °C terminalsCopper, 75 °C column: 8 AWG = 50 A [5]8 AWG copperexact match
30 A load, copper THHN, 75 °C terminalsCopper, 75 °C column: 10 AWG = 35 A; 240.4(D) limits 10 AWG copper to a 30 A breaker [5]10 AWG copperexact match
40 A load on NM-B cableCopper, 60 °C column (NM-B, NEC 334.80): 8 AWG = 40 A [5]8 AWG copperexact match
48 A continuous load (EV charger), copper THHN125 % of 48 A = 60 A (NEC 210.19); copper, 75 °C column: 6 AWG = 65 A [5]6 AWG copperexact match
48 A continuous load: breaker125 % of 48 A = 60 A (NEC 210.19) [5]60 Aexact match
100 A load, aluminum, 75 °C terminalsAluminum, 75 °C column: 1 AWG = 100 A [5]1 AWG aluminumexact match

Voltage drop calculator

ExampleThe source saysThe calculator answersAllowed difference
20 A on 12 AWG copper, 100 ft, 120 V single phase
The calculator works from resistivity at operating temperature instead of the rounded K factor, so it lands about 0.5 % higher.
2 × 12.9 × 20 A × 100 ft ÷ 6,530 cmil = 7.90 V [6]7.94 Vwithin 0.08 V
16 A on 2.5 mm² copper, 30 m, 230 V single phase2 × 0.0225 × 30 m × 16 A ÷ 2.5 mm² = 8.64 V [7]8.64 Vwithin 0.005 V
40 A on 10 mm² copper, 50 m, 400 V three phase√3 × 0.0225 × 50 m × 40 A ÷ 10 mm² = 7.79 V [7]7.79 Vwithin 0.01 V

Epoxy coverage calculator

ExampleThe source saysThe calculator answersAllowed difference
1,604 sq ft at 1 mil, 100 % solids, no wasteOne US gallon covers 1,604 sq ft at 1 mil [8]1.00 galwithin 0.005 gal
Spread rate of a 50 % solids product at 10 mils dry
The page shows the spread rate as a whole number.
1,604 × 0.50 ÷ 10 = 80.2 sq ft per gallon [8]80 sq ft/galwithin 0.5 sq ft/gal

Pool chemical calculator

ExampleThe source saysThe calculator answersAllowed difference
10 % liquid chlorine, +1 ppm FC in 10,000 gal12.79 fl oz [9]12.8 fl ozwithin 0.05 fl oz
6 % bleach, +1 ppm FC in 10,000 gal20.79 fl oz [9]20.8 fl ozwithin 0.05 fl oz
65 % cal-hypo, +1 ppm FC in 10,000 gal2.07 oz [9]2.1 ozwithin 0.05 oz
Baking soda, total alkalinity +10 ppm in 10,000 gal
The calculator uses the molar masses (84.007 g of NaHCO3 per 50.04 g of CaCO3) and gives 1.40 lb, about 5 % under Pool Math's figure. Add in portions and retest.
1.47 lb [9]1.40 lbwithin 0.08 lb
Stabilizer, CYA +10 ppm in 10,000 gal
The calculator assumes a 99 % pure product, so it asks for 1 % more.
13.35 oz of 100 % cyanuric acid [9]13.5 ozwithin 0.2 oz
Salt +1,000 ppm in 10,000 gal
The calculator assumes 99 % pure salt.
83.7 lb [9]84.30 lbwithin 1 lb

Lye calculator

ExampleThe source saysThe calculator answersAllowed difference
1,000 g olive oil, 5 % superfat128.6 g NaOH [10]128.7 g NaOHwithin 0.2 g
180 g olive, 144 g coconut, 90 g shea, 36 g castor, 5 % superfat
Published recipes round to whole grams, and SAP values differ a little between tables.
63 g NaOH [11]63.5 g NaOHwithin 1 g

Baker's percentage calculator

ExampleThe source saysThe calculator answersAllowed difference
1,000 g flour at 75 % hydration: water75 % of 1,000 g = 750 g [12]750 gwithin 0.5 g
1,000 g flour, 750 g water, 200 g starter at 100 %: true hydration(750 + 100) ÷ (1,000 + 100) = 77.3 % [12]77.3 %within 0.05 %

Sources

  1. Arkema, Forane® Refrigerants Pressure Temperature Chart, PPC/SDC 05-2025 (NIST REFPROP 10.0). Read 25.10.2026.
  2. Chemours, Thermodynamic Properties of Opteon™ XL41 (R-454B), Engineering (I/P) Units, 1 °F steps; gauge pressure = table psia − 14.696. Values as pinned in the HVAC Charge app's tests.
  3. CoolProp 8.0 (NIST reference equations of state), saturation pressure. Values as pinned in the HVAC Charge app's tests.
  4. NEC (NFPA 70) 2023, Chapter 9, Table 8, Conductor Properties.
  5. NEC (NFPA 70) 2023, Table 310.16, ampacities at 30 °C ambient, not more than three current-carrying conductors.
  6. K-factor voltage drop formula for copper, VD = 2 × K × I × L ÷ CM with K = 12.9 Ω·cmil/ft.
  7. IEC 60364-5-52, Annex G: u = b × ρ × L × I ÷ S at unity power factor, ρ = 0.0225 Ω·mm²/m for copper.
  8. US liquid gallon = 231 cubic inches (NIST Handbook 44, Appendix C). 231 in³ spread 0.001 in thick = 1,604 sq ft.
  9. Trouble Free Pool, Pool Math classic calculator (troublefreepool.com/calc.html). Read 25.10.2026.
  10. SoapCalc oil list and lye calculator (soapcalc.net). Snapshot of 25.10.2026.
  11. The Soapery / Low Impact, simple cold process soap recipe without palm oil (lowimpact.org, 2022).
  12. Baker's percentage, total-formula method (King Arthur Baking, Baker's percentage; Wikipedia, Baker percentage).