Methodology and sources
Which published tables and editions each calculator uses, what it assumes, and where it stops. If a number here is wrong, I want to know.
How the numbers are made and checked
Every calculator on this site uses a published table or a formula that is named on its page and listed below. The browser calculators run the same formulas as the Dre Dev phone apps.
They are checked in two ways. Each app has its own tests against the published values. On this site, 31 checked examples put a row from a source next to the calculator's answer; they run through the calculator code every time the site is built, and the build stops if one is outside its tolerance.
The tools are made and checked by Andrii Zhukovskyi, the developer. "Checked" means compared with the sources below. No outside trade professional has reviewed these pages yet. The sources were last read against the examples on 12 November 2026.
The code that builds the site, the formulas and the examples are public: github.com/andronaft/dredev-tools.
Limits that apply to every tool
Reference only. A result depends on what you enter and on the published tables named on this page. Before you buy materials, size a circuit, charge a system or dose chemicals, check it against the code in force where you work, the product label and the manufacturer's instructions. These tools come with no warranty.
Found a wrong number? Send it with the page, what you entered and the source you compared with. Corrections are listed in the changelog.
Superheat & subcooling calculator and PT charts
Tables and formulas
- Pressure–temperature rows as printed by the manufacturer, one row every 5 °F. The source of each refrigerant is listed under the table below and on its chart page.
- Gauge pressure is turned into absolute pressure with the standard atmosphere, 14.696 psia. Between rows the calculator interpolates along the vapor-pressure curve: straight in ln(P) against 1/T.
- For blends with glide, superheat is read from the vapor (dew) column and subcooling from the liquid (bubble) column.
- Cross-checks done in the HVAC Charge app the data comes from: Arkema's R-454B columns agree with Chemours' 1 °F table for Opteon™ XL41 within 0.06 psi, and the interpolated values agree with CoolProp 8.0 (NIST reference equations).
Assumptions
- Sea-level atmospheric pressure. The calculator does not correct a gauge reading for altitude.
- Readings are taken at the service valves, as the questions on the page describe.
Limits
- Answers only inside the printed range of the chart; outside it the page says so instead of extrapolating.
- It reports superheat or subcooling. It does not tell you the target for a unit: that comes from the manufacturer's charging instructions.
- Handling refrigerants requires EPA Section 608 certification in the US.
Wire size calculator
Tables and formulas
- NEC (NFPA 70) 2023, Table 310.16: ampacities of copper and aluminum conductors in the 60, 75 and 90 °C columns, 14 AWG to 500 kcmil.
- NEC 240.4(D) for small conductors, 334.80 for NM-B cable (60 °C column), 210.19(A)(1) and 215.2 for the 125 % continuous-load rule.
- Standard breaker ratings from 15 A to 600 A. A conductor may sit on the next standard breaker size above its ampacity, as the code allows up to 800 A.
Assumptions
- 30 °C ambient and no more than three current-carrying conductors: no temperature or bundling correction.
- The lower of the insulation column and the terminal rating you pick (60 or 75 °C).
- The optional voltage drop check uses 3 % at full load and unity power factor.
Limits
- No derating, no motor or HVAC nameplate rules, no parallel conductors, nothing above 500 kcmil or 600 A.
- Local amendments and the edition your jurisdiction has adopted may differ from NEC 2023.
- It sizes the ungrounded conductors only; grounding conductors, conduit fill and box fill are not checked.
Voltage drop calculator
Tables and formulas
- NEC sizes: conductor areas from NEC Chapter 9, Table 8, with resistivity at 20 °C (copper 0.017241, aluminum 0.028264 Ω·mm²/m) raised by 25 % for operating temperature.
- IEC sizes: IEC 60364-5-52, Annex G, with ρ = 0.0225 Ω·mm²/m for copper and 0.036 for aluminum, and a reactance of 0.08 mΩ/m on AC.
- The 3 % and 5 % limits are the NEC informational notes and the IEC 60364-5-52 guidance; they are recommendations.
Assumptions
- One-way length; the formula counts the return conductor (or the three phases).
- A balanced load and one conductor per phase.
Limits
- It checks voltage drop only. Size the conductor for ampacity and overcurrent protection as well.
- The NEC-mode result runs about 0.5 % above the rounded K-factor formula (K = 12.9).
AWG to mm² converter
Tables and formulas
- NEC Chapter 9, Table 8: areas in circular mils, converted with 1 cmil = 0.000506707 mm².
- Metric sizes are the IEC 60228 series.
Assumptions
- Area only.
Limits
- An equal or larger area does not prove equal ampacity: insulation, installation method and the code in force decide that.
Epoxy coverage calculator
Tables and formulas
- One US gallon is 231 cubic inches, so it covers 1,604 sq ft at 1 mil. Gallons = area × mils ÷ (1,604 × solids by volume) × (1 + waste).
Assumptions
- Thickness is the dry film thickness. Solids by volume comes from the product's technical data sheet.
- Kits are rounded up to whole kits.
Limits
- Surface profile and porosity are covered only by the waste percentage you enter.
- It does not know a product's recoat window, pot life or minimum film thickness: read the data sheet.
Pool chemical calculator
Tables and formulas
- Doses come from stoichiometry: ppm × litres = milligrams, converted by molar mass and label strength.
- Liquid chlorine by trade percent; bleach by weight percent with the density formula used by Trouble Free Pool's Pool Math; baking soda as 84.007 g of NaHCO3 per 50.04 g of CaCO3.
- Cross-checked against Pool Math's classic calculator (read 25 October 2026).
Assumptions
- Stabilizer and salt are taken as 99 % pure.
- The pool volume you enter is right.
Limits
- It only raises free chlorine, total alkalinity, stabilizer and salt. It does not handle pH, calcium or CSI; the PoolPro app does.
- Dichlor and cal-hypo also add stabilizer or calcium; the page says so but does not count them.
- Add in portions and retest. Never mix chlorine products with each other or with acid.
Baker's percentage calculator
Tables and formulas
- Baker's percentages as defined by King Arthur Baking and the total-formula method: every ingredient is a share of the flour weight.
- True hydration = (water + water in the starter) ÷ (flour + flour in the starter).
Assumptions
- The starter percentage is a share of the flour in the bowl, as home recipes write it.
Limits
- Arithmetic on your own numbers. It ships no fermentation times, temperatures or nutrition data.
Lye calculator
Tables and formulas
- Saponification (SAP) values from the SoapCalc oil list, snapshot of 25 October 2026, for 19 common oils.
- NaOH SAP = KOH SAP × 39.997 ÷ 56.106 (molar masses). Lye = Σ(oil grams × SAP) × (1 − superfat) ÷ purity. Water follows from the lye concentration.
- In the Lye Calc app the same values are checked against a second published table and against published recipes.
Assumptions
- Sodium hydroxide only on this page; the app also does KOH and dual lye.
Limits
- Oils vary between suppliers and harvests: treat the result as a starting point and run a new recipe through a second calculator.
- Lye is caustic: gloves, goggles, ventilation, and always add lye to water.
Roof pitch chart and shingle bundles calculator
Tables and formulas
- Slope factor = √(12² + rise²) ÷ 12; hip and valley factor = √(2 × 12² + rise²) ÷ 12. Exact geometry, the same as in the RoofCalc app.
- One square is 100 sq ft; three bundles to the square (Owens Corning, read 12 November 2026), 33.3 sq ft per bundle.
Assumptions
- Every plane of the roof has the same pitch.
- The footprint includes the overhangs.
Limits
- Field shingles only: starter, ridge cap, underlayment, drip edge and nails are not counted.
- Coverage per bundle differs between products: read the wrapper.
- Code limits for low slopes follow the IRC; your local code may differ.
Concrete slab calculator and slab sizes
Tables and formulas
- Volume = length × width × thickness; 27 cu ft to the cubic yard; ready-mix rounded up to the next quarter yard.
- Bag yields from the QUIKRETE Concrete Mix No. 1101 data sheet: 0.60, 0.45 and 0.30 cu ft for 80, 60 and 40 lb bags (read 12 November 2026).
- Rebar: bars each way = spaces rounded up + 1, #4 bar at 0.668 lb per foot (ASTM A615), 20 ft sticks, laps of 40 bar diameters.
Assumptions
- A flat rectangular slab of even thickness.
- 10 % extra unless you change it; bars 3 in clear of the edges.
Limits
- It sizes an order. Thickness, reinforcement, joints and base come from your plans, engineer or building department.
- Lap length depends on the concrete, the bar and the spacing: the engineer gives it.
Garage floor epoxy calculator
Tables and formulas
- Gallons = area × mils ÷ (1,604 × solids by volume) × (1 + waste), as on the epoxy coverage calculator.
- System presets (solids and thickness) are the CoatCalc app's mid-range values from makers' data sheets (read October 2026).
Assumptions
- One coat of one product at the dry film thickness you enter.
Limits
- The garage sizes are examples, not a standard: measure the floor.
- Use the solids and coverage on your own product's data sheet.
Pool chlorine calculator
Tables and formulas
- ppm × litres = milligrams of chlorine, divided by the product's label strength: the same maths as the pool chemical calculator and the PoolPro app.
- Stabilizer from dichlor and trichlor and calcium from cal-hypo follow from the molar masses.
- Free chlorine by stabilizer level: Trouble Free Pool's FC/CYA chart (read 12 November 2026).
Assumptions
- The pool volume and the strength on the label are right.
Limits
- The product label comes first, including its largest single dose.
- Never mix pool chemicals. Add in portions and test again.
- It does not handle pH, alkalinity or water balance.
Shift pattern calendars
Tables and formulas
- Each rota is written out day by day and counted: hours per week = hours per cycle ÷ cycle days × 7; days off a year = days off per cycle ÷ cycle days × 365.25.
- The sequences are those of the ShiftWise app where it has the pattern, and of the sources named on each page (read 12 November 2026).
Assumptions
- Every shift has the same length; the calendar year is counted day by day.
Limits
- Scheduled hours only: unpaid breaks, leave, overtime and public holidays are not counted.
- Employers run variants of every pattern: go by your own rota.
Mead ABV and honey calculators
Tables and formulas
- ABV = (OG − FG) × 131.25, and Michael Hall's formula (Zymurgy, Summer 1995) for strong meads and wines, as published by Brewer's Friend.
- Brix or Plato to SG: 1 + °P ÷ (258.6 − °P ÷ 258.2 × 227.1); SG to Plato by the ASBC polynomial.
- Honey: 35 gravity points per pound per US gallon (Ken Schramm, The Compleat Meadmaker, 2003).
- Mead sweetness and strength classes from the BJCP Mead Guidelines (read 12 November 2026).
Assumptions
- Readings are taken with a hydrometer at its calibration temperature.
- The batch volume is the finished must, honey included.
Limits
- Honey varies with its water content: measure the gravity after mixing.
- A refractometer reads too high once alcohol is present; the page does not correct for it.
- Honey or sugar added during fermentation is not counted unless you add its points to the original gravity.
EC to ppm converter and crop chart
Tables and formulas
- ppm = EC in µS/cm × 0.5 for NaCl-calibrated meters and × 0.7 for 442-type solutions (Hanna Instruments, read 12 November 2026).
- Crop EC and pH ranges: Oklahoma State University Extension, HLA-6722, Table 2, for 23 vegetables, herbs and flowers, as the GrowLab app ships them.
Assumptions
- Your meter is calibrated and temperature-compensated.
Limits
- The 640 scale is arithmetic only: no meter maker's manual was found that confirms a 0.64 factor.
- Crop ranges are starting points from one fact sheet; variety, water and climate move them. Follow your nutrient maker's label.
Candle fragrance and wax calculators
Tables and formulas
- Fragrance = wax weight × load, with the load as a percentage of the wax.
- Wax and fragrance in a jar = weight of water to the fill line × 0.86 (Armatage Candle Company; common waxes are 82–95 % as dense as water), then wax = fill ÷ (1 + load).
- Listed fragrance loads for five container waxes from their CandleScience product pages (read 12 November 2026).
Assumptions
- The wax factor 0.86 until you measure your own from a test candle.
Limits
- A listed load is the supplier's figure for container candles, not a promise for your wick, jar and oil: test burn.
- It does not pick a wick.
Espresso ratio calculator
Tables and formulas
- Brew ratio = espresso out ÷ coffee in, by weight.
- Style names use the Dial In app's lines (ristretto up to 1:1.5, normale to 1:2.5, lungo beyond); La Marzocco Home's ranges are shown next to them.
Assumptions
- Both weights are in grams.
Limits
- There is no single standard for ristretto, normale and lungo. Taste decides, not the ratio.
Yarn yardage and gauge calculators
Tables and formulas
- Yarn = yarn in your swatch × project area ÷ swatch area; yarn in the swatch = swatch weight × length on the ball band ÷ weight on the ball band.
- Balls to buy are rounded up, as in the RowKeeper app. Stitches to cast on = gauge ÷ 4 × width.
- Usual gauge by yarn weight: Craft Yarn Council, Standard Yarn Weight System (read 12 November 2026).
Assumptions
- The project is worked in the same yarn, needles and stitch as the swatch.
- A hat is counted as a tube, so it comes out a little generous.
Limits
- No yardage tables: the result is only as good as your swatch.
- Shaping, cables, lace and borders change the amount.
Sources of the refrigerant PT charts
| Source | Refrigerants |
|---|---|
| Arkema Forane® Pressure Temperature Chart (PPC/SDC 05-2025) | R-410A, R-454B, R-32, R-22, R-134a, R-404A, R-407C, R-448A, R-449A, R-452A, R-513A |
| Arkema Forane® Pressure-Temperature Wall Chart, Americas (2019) | R-407A, R-507A, R-427A, R-408A, R-409A |
| Chemours, Thermodynamic Properties of Opteon™ YF, Engineering (I/P) Units | R-1234yf |
| NIST Chemistry WebBook, SRD 69, saturation properties | R-290, R-600a, R-744, R-717, R-12 |
Arkema and Bryant/Carrier documents were retrieved on 25 October 2026; Chemours Opteon™ YF and the NIST Chemistry WebBook on 26 October 2026.